• NU-Air – NU 500 F-P Light Commercial HRV with Fan Shut Down Defrost 460 cf...

    • NU-Air – NU 500 F-P Light Commercial HRV with Fan Shut Down Defrost 460 cfm
    • Two forward curve blowers work to bring fresh air into the space and exhaust an equal amount of stale air.
    • Incoming fresh air is filtered before flowing through the heat exchange core.
    • Warm fresh air is distributed through an independent ductwork system or an existing air distribution system.
    • Stale, humid air flows through the cross-flow heat exchanger and transfers the heat to the incoming fresh air.
    2,478.25 CAD3,029.00 CAD
  • Nu-Air – NU145 Energy Star Windsor Series Residential HRV for up to 2500 s...

    • Furnace interlock options: commands furnace blower when HRV is on or only on high speed
    • Intelligent Defrost: duration and interval adjust to outdoor conditions below -5°C (23°F).
    • 24 V circuit protection with self resetting fuse.
    • Defrost: When outdoor temperature falls to -5°C (23°F), an automatic timed defrost cycle is initiated. The fresh air motor will go to high speed and the exhaust air motor will turn off. A damper will shut off the cold supply port, directing ambient air through the core for defrosting. The unit will resume normal operation for a fixed duration, then the processor will read outdoor temperature and initiate defrost as necessary
    1,143.36 CAD1,499.00 CAD
  • Nu-Air – ES150 Residential HRV Energy Star Windsor Series Residential HRV ...

      • Furnace interlock options: commands furnace blower when HRV is on or only on high speed
      • Intelligent Defrost: duration and interval adjust to outdoor conditions below -5° C (23° F).
      • 24 V circuit protection with self resetting fuse.
      • In defrost and recirculation modes, this unit will not induce indoor negative pressure nor recycle exhaust air; rather, it will redistribute ambient room air.
    1,285.32 CAD1,610.00 CAD
  • Nu-Air – ES100 Residential HRV Energy Star 118 cfm for Homes up to 2500 sq...

    • Furnace interlock options: commands furnace blower when HRV is on or only on high speed
    • Intelligent Defrost: duration and interval adjust to outdoor conditions below -5° C (23° F).
    • 24 V circuit protection with self resetting fuse.
    • Defrost: When outdoor temperature falls to -5° C (23° F), an automatic timed defrost cycle is initiated. The fresh air motor will go to high speed and the exhaust air motor will turn off. A damper will shut off the cold supply port, directing ambient air through the core for defrosting. The unit will resume normal operation for a fixed duration, then the processor will read outdoor temperature and initiate defrost as necessary.
    1,188.00 CAD1,489.00 CAD